Back to the main page.
Bug 1418 - ft_selectdata_old fails on output of ft_connectivityanalysis when called as: selectdata(data,'channel',chansel)
Status | CLOSED FIXED |
Reported | 2012-04-12 13:47:00 +0200 |
Modified | 2012-06-01 14:08:57 +0200 |
Product: | FieldTrip |
Component: | core |
Version: | unspecified |
Hardware: | PC |
Operating System: | Windows |
Importance: | P1 critical |
Assigned to: | Jan-Mathijs Schoffelen |
URL: | |
Tags: | |
Depends on: | |
Blocks: | |
See also: |
Roemer van der Meij - 2012-04-12 13:47:38 +0200
This was detected by test_tutorial_coherence, which threw an error when trying to plot chancmb data using ft_multiplotER. It fails in ft_selectdata_old on line 572, stating, 'not yet implemented'. It refers to selecting channel combinations when data.label is not present. The call is performed on output by ft_connectivityanalysis, which doesn't have a data.label field. As this is a test_script for the tutorial, and thus it would have worked before, I assume one of the two following has occured: 1) ft_connectivityanalysis previously had a output.label field in output, next to labelcmb. 2) ft_selectdata previously was able to select chancmbs without a data.label field. JM, I added you to the bug as case #1 seems a bit more likely than case #2. Was the field removed from the output by any chance?
Roemer van der Meij - 2012-04-12 13:48:10 +0200
Added JM to CC