Robert Oostenveld - 2012-06-11 17:44:31 +0200
At the moment the head is plotted upside down... we can do better than that!
Jan-Mathijs Schoffelen - 2012-07-18 14:07:26 +0200
The tutorial may need to be adjusted a bit, in that the subject specific mri should be first ft_volumeresliced and only then ft_sourceinterpolated. Then the upside will be up. This means that some code needs to be added to the tutorial and to test_tutorial_xxx.
Arjen Stolk - 2012-07-25 10:22:24 +0200
The brain is now upside up again. Added line 'mri = ft_volumereslice([], mri)' both to the tutorial wiki page http://fieldtrip.fcdonders.nl/tutorial/coherence?&#appendix_1localisation_of_neuronal_sources_coherent_with_the_emg_using_beamformers and to test_tutorial_coherence.m