Jörn M. Horschig - 2012-07-02 11:54:24 +0200

I fixed it in my repository by adding around line 84 switch cfg.dimord case 'voxel' nchan = size(dat, 1); nfreq = 1; ntime = 1; [nsmpls,nrepl] = size(dat); (...) works fine, should be alright. I just don't know whether this actually makes sense (I beamed gamma, and want to check subject individual differences for selectint a ROI) - does it?


Robert Oostenveld - 2012-07-02 12:07:40 +0200

I don't think it makes sense. The A versus B selection pertains to different selections along the time axis. If your input data (one structure) does not contain time, actvsblT should not allow you to compute anlything.


Jörn M. Horschig - 2013-01-23 15:02:19 +0100

okidoki, wontfix


Robert Oostenveld - 2019-08-10 12:02:58 +0200

This closes a whole series of bugs that have been resolved (either FIXED/WONTFIX/INVALID) for quite some time. If you disagree, please file a new issue describing the issue on https://github.com/fieldtrip/fieldtrip/issues.