Stephen Whitmarsh - 2014-08-29 09:27:48 +0200
When both EEG and MEG sensors are detected read_sens only outputs EEG: Warning: both electrode and gradiometer information is present, returning the electrode information > In ft_read_sens at 168 Would it be possible to somehow flag either EEG or MEG sensors, or perhaps nicer, when two output arguments are given, output both? Cheers, Stephen
Robert Oostenveld - 2014-08-29 15:10:41 +0200
Ft_read-_sens has the option senstype, which can be EEG or MEG. It is not documented.
Jan-Mathijs Schoffelen - 2014-09-10 14:02:04 +0200
this is relevant in light of the stockholm workshop. at the moment a lot of code excludes the presence of both an elec and grad field (so it does not only pertain to ft_read_sens), because it's often like this: if isfield(data, 'elec') elseif isfield(data, 'grad') end However, sometimes having both an elec and grad field makes sense. (e.g in neuromag data). First thing to do would be to inventorize where these instances occur. One obvious place would e.g. be ft_appenddata, where it should be possible to append meg with eeg data.
Robert Oostenveld - 2017-04-21 10:16:15 +0200
This was already working for quite some time for Elekta fif datasets. Earlier this week I also implemented it for CTF datasets.
Robert Oostenveld - 2019-08-10 12:34:31 +0200
This closes a whole series of bugs that have been resolved (either FIXED/WONTFIX/INVALID) for quite some time. If you disagree, please file a new issue on https://github.com/fieldtrip/fieldtrip/issues.