Robert Oostenveld - 2010-12-17 13:46:21 +0100

>> hdr = ft_read_header('mi_av17_112_01-A_CH002.nex'); >> hdr hdr = nChans: 9 Fs: 1000 nSamples: 35893548 nTrials: 1 nSamplesPre: 0 label: {9x1 cell} FirstTimeStamp: 0 TimeStampPerSample: 40 orig: [1x1 struct] whereas the file contains a mix of 1kHz and 40kHz


Robert Oostenveld - 2010-12-17 13:47:44 +0100

the bug is at hdr.Fs = orig.varheader(adindx(1)).wfrequency; % take the sampling frequency from the first A/D channel


Robert Oostenveld - 2010-12-17 13:58:03 +0100

search for adindx(1), there are more bugs like this