Eelke Spaak - 2011-05-17 11:48:22 +0200

See also bug 658. For systems with both magnetometers and gradiometers, the power values might be in different orders of magnitude. @Eliezer: I assume the missing channels in your example figure were due to a channel selection, right? Or was them missing also part of the bug? I did not get any missing channels.


Eliezer Kanal - 2011-05-17 19:36:51 +0200

Yes, that was due to channel selection. That was a particularly noisy dataset :)


Eelke Spaak - 2011-07-20 15:22:13 +0200

This should be implemented in the next version. Could you let me know if it works out, Eli? I was only able to test it with simulated data, we have no proper Neuromag-306 test data here.


Eelke Spaak - 2011-08-18 09:58:12 +0200

closing some resolved bugs