Bug 804 - some MEG channels do not have correct coil positions and orientations
Status | CLOSED WORKSFORME |
Reported | 2011-07-07 17:23:00 +0200 |
Modified | 2011-11-11 11:19:56 +0100 |
Product: | FieldTrip |
Component: | yokogawa |
Version: | unspecified |
Hardware: | PC |
Operating System: | Mac OS |
Importance: | P1 normal |
Assigned to: | Kaoru Amano |
URL: | |
Tags: | |
Depends on: | |
Blocks: | |
See also: |
Robert Oostenveld - 2011-07-07 17:23:02 +0200
the following channels in hdr.grad seem to have incorrect coil positions 'RM401' 'RM402' 'RM403' 'RM404' 'RM405' 'RM406' 'RM407' 'RM408' 'RM409' 'RM410' 'RM411' 'RM412'
Kaoru Amano - 2011-07-16 11:00:55 +0200
Which data file are you talking about? I think the loading function itself is fine and the position of some sensors is wrong even before we load the date into FT. So I don't think it's necessary to fix FT codes.
Tilmann Sander-Thommes - 2011-07-18 12:44:22 +0200
Created attachment 101 pciture of yokogawa software
Tilmann Sander-Thommes - 2011-07-18 12:45:04 +0200
The "RMx" refers to reference magnetometer sensors about 15 cm aways from the helmet, but within the Dewar. Yokogawa does not give location and orientation for them in the software (MEG160 -> Edit -> Channel Info: See attached figure). The RMs were included upon the wish of Vladimir / SPM to have all possible sensors. The RMs in other Yokogawa systems have position and orientation. If the absence of pos/ori causes trouble they should probably be removed at some stage. Till
Kaoru Amano - 2011-07-29 12:55:03 +0200
Today, I talked to a Yokogawa person, and he mentioned that they couldn't calibrate the location and orientation of reference sensors though they tried to do so. Robert, what do you think is the best way to deal with the Yokogawa reference sensors, whose position and orientation are not available.
Tilmann Sander-Thommes - 2011-10-17 17:28:00 +0200
Hi Robert, The question of the missing Yokogawa Reference Magnetometer positions is still open. I suggest to remove them from the grad-structure as they cannot be used in a forward calculation. To force a decision here I will remove them from the grad-structure if nobody objects. Yours, Till
Kaoru Amano - 2011-10-18 04:45:40 +0200
Just to make sure, FT doesn't give an error when we load the data of reference sensors, which is not defined in grad, right? I don't use reference sensors for now, but might use them for noise reduction in the future.
Tilmann Sander-Thommes - 2011-10-18 11:14:56 +0200
Hi Kaoru, If you to use the reference channels for noise reduction you load all channels in ft_preprocessing and then you can do the denoising. If you use SPM straight away you would not do denoising and then you are fine with gradiometer channels only. Is that correct and do you plan it that way ? Yours, Till
Kaoru Amano - 2011-10-18 12:24:56 +0200
If all the functions in FT don't complain about the data structure including the channels without the definition in data.grad.label, removing Yokogawa Reference Magnetometer positions is fine for me.
Tilmann Sander-Thommes - 2011-10-20 17:29:12 +0200
Dear Kaoru, I am still struggling with channel sequences from your system. I will attach a file, which I believe is originally from you. But it does not have any reference channels at all (MEG160 -> Edit -> Channel Info). Can you attach here a small file with your current (final ?) channel arrangement including reference channels, if there are any ? Many thanks, Till
Tilmann Sander-Thommes - 2011-10-20 17:30:10 +0200
Created attachment 168 yokogawa data file file wrt previous comment
Robert Oostenveld - 2011-10-21 15:40:57 +0200
using the attached test file, I have made the script test_bug804 which basically contains cd /home/common/matlab/fieldtrip/data/test/bug804 cfg = []; cfg.dataset = 'amano.ave'; data = ft_preprocessing(cfg); ft_plot_sens(data.grad); the script now runs through without a problem, hence I changed the status into "worksforme"