Albert Bakker - 2010-06-04 11:41:35 +0200
When I'm calling ft_topoplotER in my script the following error appears: ??? Error using ==> ft_topoplotER at 475 labels in data and labels in layout do not match I'm trying to load an ASA-layout (file on 'ftp://ftp.fcdonders.nl/pub/incoming/': waveguard64.elc) Discovered that the error originates in: read_asa_elc -> reformat the electrode labels into an appropriately sized cell array goes wrong (check file on 'ftp://ftp.fcdonders.nl/pub/incoming/': lab.mat for the wrong and the correct output of read_asa_elc) If I changed it so it is working, I got the following matlab-output of ft_prepare_layout: creating layout from electrode file D:\...\DATA\waveguard64.elc creating layout for ext1020 system than the electrode-layout was shifted 90 degree CW to the head-layout. Build Date & Platform: fieldtrip-20100531; Vista SP2
Robert Oostenveld - 2010-06-08 11:31:08 +0200
the problematic file was written with a later version of ASA than the version fieldtrip is tested with. The *.elc file contained additional information which messed up the channel labels. I have made a fix.