Back to the main page.
Bug 950 - ft_megrealign does not properly take balancing into account
| Status | CLOSED FIXED |
| Reported | 2011-09-12 11:35:00 +0200 |
| Modified | 2011-12-07 16:00:25 +0100 |
| Product: | FieldTrip |
| Component: | core |
| Version: | unspecified |
| Hardware: | PC |
| Operating System: | Mac OS |
| Importance: | P1 critical |
| Assigned to: | Jan-Mathijs Schoffelen |
| URL: | |
| Tags: | |
| Depends on: | |
| Blocks: | |
| See also: |
Jan-Mathijs Schoffelen - 2011-09-12 11:35:50 +0200
at some point the gradiometer structure and the volume conductor model are processed by prepare_headmodel (which is a wrapper around ft_prepare_vol_sens), where only the MEG sensor coils are kept. Apart from this being not entirely correct (e.g. 3d order gradient balancing) it causes a crash when later on in the function some plotting is done (due to a crash in channelposition)